Powertrace Technologies
HOME→INDUSTRIES→
PRODUCTS→
Battery Energy Storage Systems (BESS)Battery Management Systems (BMS)Energy Management Systems (EMS)
ABOUT US→
Our CompanySolutions
BLOGS→CAREERS→Contact Us
VYOM series · EMS

The brain of your microgrid

VYOM EMS coordinates solar, battery, diesel and grid in real time, cutting peak demand, arbitraging tariffs and keeping your plant running through outages. Software built 100% in-house, with your data staying in India.

20-40%
Monthly electricity cost reduction
2000+
System parameters monitored
20%
Less battery degradation per year
< 20 ms
On/off-grid switchover
EMS Platform|
VYOM edge controller

The hardware that runs your site

One rugged box in your control panel talks to every asset on site and keeps running even if the internet drops.

Powertrace VYOM edge controller with Ethernet, power and I/O terminals
1
Power input
9-36 V DC with surge protection.
2
4 × Ethernet
Modbus TCP to the PCS, energy meters and the cloud.
3
Digital inputs
Breaker status, fire alarm and DG run signals.
4
CAN · RS-485 · analog I/O
CAN to the battery BMS, Modbus RTU to meters, plus analog sensors.
5
Digital outputs
Start the DG, trip breakers and drive alarm relays.
Inside the controller

Designed board, industrial I/O

Isolated field terminals, the processor that runs VYOM's dispatch logic, and the interfaces that link every asset on site, designed by our team.

VYOM controller circuit board render
Core capabilities

What VYOM does for your plant

Fully autonomous once commissioned. Three of these run live in the simulator on our homepage.

01

Peak shaving

Run in simulator ↗
02

ToD arbitrage

Run in simulator ↗
03

Backup power

Run in simulator ↗
04

Predictive load management

05

Power factor correction

06

Battery protection

How it decides

Clear priorities, every 100 milliseconds

Each cycle, VYOM checks four things in a fixed order. The first one that applies decides what the battery does. Pick a scenario to see where it stops.

Try a scenario
01
Manual mode set?
Operator override
NO → next
ThenYour team’s setpoints run the site. Automation steps aside.
02
Any safety limit hit?
Safety
NO → next
ThenTemperature, cell voltage, SoC or fire alarm: the battery stops instantly and the alert escalates.
03
Grid lost?
Grid state
NO → next
ThenDetected within 100 ms. The breaker opens and the battery forms the grid; the DG is only a backup.
04
Normal operation
Dispatch
RUNS
What VYOM doesShave peaks, arbitrage ToD tariffs, recharge within the headroom, curtail solar to avoid export.
The VYOM platform

Your whole site, on one screen

Control and monitor from your phone, iPad, laptop or the local station.

VYOM EMS dashboard showing BESS overview, live energy flow between grid, batteries, solar, diesel gensets and factory, and PCS operating modes
Ready to deploy · 4-6 weeks

From site survey to savings

Remote diagnosis, 24/7 monitoring and DISCOM tariff updates within days once you are live.

Week 1
Site survey & design
Week 2-3
Hardware delivery
Week 3-4
Installation & integration
3-5 days
EMS commissioning on-site
Week 4-6
Go-live
≤ 4 weeks
First savings observed
Free 15-year ROI projection

See what VYOM can save your facility

Share your monthly 15-minute interval electricity bill and our engineers will right-size your BESS and project your savings over 15 years.